{"ID":2896165,"CreatedAt":"2026-06-01T04:54:23.091178241Z","UpdatedAt":"2026-06-01T04:54:23.091178241Z","DeletedAt":null,"paper_url":"https://arxiv.org/abs/2507.07811","arxiv_id":"2507.07811","title":"Patient-specific vs Multi-Patient Vision Transformer for Markerless Tumor Motion Forecasting","abstract":"Background: Accurate forecasting of lung tumor motion is essential for precise dose delivery in proton therapy. While current markerless methods mostly rely on deep learning, transformer-based architectures remain unexplored in this domain, despite their proven performance in trajectory forecasting. Purpose: This work introduces a markerless forecasting approach for lung tumor motion using Vision Transformers (ViT). Two training strategies are evaluated under clinically realistic constraints: a patient-specific (PS) approach that learns individualized motion patterns, and a multi-patient (MP) model designed for generalization. The comparison explicitly accounts for the limited number of images that can be generated between planning and treatment sessions. Methods: Digitally reconstructed radiographs (DRRs) derived from planning 4DCT scans of 31 patients were used to train the MP model; a 32nd patient was held out for evaluation. PS models were trained using only the target patient's planning data. Both models used 16 DRRs per input and predicted tumor motion over a 1-second horizon. Performance was assessed using Average Displacement Error (ADE) and Final Displacement Error (FDE), on both planning (T1) and treatment (T2) data. Results: On T1 data, PS models outperformed MP models across all training set sizes, especially with larger datasets (up to 25,000 DRRs, p \u003c 0.05). However, MP models demonstrated stronger robustness to inter-fractional anatomical variability and achieved comparable performance on T2 data without retraining. Conclusions: This is the first study to apply ViT architectures to markerless tumor motion forecasting. While PS models achieve higher precision, MP models offer robust out-of-the-box performance, well-suited for time-constrained clinical settings.","short_abstract":"Background: Accurate forecasting of lung tumor motion is essential for precise dose delivery in proton therapy. While current markerless methods mostly rely on deep learning, transformer-based architectures remain unexplored in this domain, despite their proven performance in trajectory forecasting. Purpose: This work...","url_abs":"https://arxiv.org/abs/2507.07811","url_pdf":"https://arxiv.org/pdf/2507.07811v1","authors":"[\"Gauthier Rotsart de Hertaing\",\"Dani Manjah\",\"Benoit Macq\"]","published":"2025-07-10T14:40:52Z","proceeding":"cs.CV","tasks":"[\"cs.CV\"]","methods":"[\"Vision Transformer\",\"Transformer\"]","has_code":false}