{"ID":2874943,"CreatedAt":"2026-06-01T04:54:23.091178241Z","UpdatedAt":"2026-06-01T04:54:23.091178241Z","DeletedAt":null,"paper_url":"https://arxiv.org/abs/2509.03137","arxiv_id":"2509.03137","title":"A Neural Network Approach to Multi-radionuclide TDCR Beta Spectroscopy","abstract":"Liquid scintillation triple-to-doubly coincident ratio (TDCR) spectroscopy is widely adopted as a standard method for radionuclide quantification because of its inherent advantages such as high precision, self-calibrating capability, and independence from radioactive reference sources. However, multiradionuclide analysis via TDCR faces the challenges of limited automation and reliance on mixture-specific standards, which may not be easily available. Here, we present an Artificial Intelligence (AI) framework that combines numerical spectral simulation and deep learning for standard-free automated analysis. $β$ spectra for model training were generated using Geant4 simulations coupled with statistically modeled detector response sampling. A tailored neural network architecture, trained on this dataset covering various nuclei mix ratio and quenching scenarios, enables autonomous resolution of individual radionuclide activities and detecting efficiency through end-to-end learning paradigms. The model delivers consistent high accuracy across tasks: activity proportions (mean absolute error = 0.009), detection efficiencies (mean absolute error = 0.002), and spectral reconstruction (Structural Similarity Index = 0.9998), validating its physical plausibility for quenched $β$ spectroscopy. This AI-driven methodology exhibits significant potential for automated safety-compliant multiradionuclide analysis with robust generalization, real-time processing capabilities, and engineering feasibility, particularly in scenarios where reference materials are unavailable or rapid field analysis is required.","short_abstract":"Liquid scintillation triple-to-doubly coincident ratio (TDCR) spectroscopy is widely adopted as a standard method for radionuclide quantification because of its inherent advantages such as high precision, self-calibrating capability, and independence from radioactive reference sources. However, multiradionuclide analys...","url_abs":"https://arxiv.org/abs/2509.03137","url_pdf":"https://arxiv.org/pdf/2509.03137v1","authors":"[\"Li Yi\",\"Qian Yang\"]","published":"2025-09-03T08:40:02Z","proceeding":"cs.LG","tasks":"[\"cs.LG\",\"cs.AI\",\"nucl-ex\",\"physics.comp-ph\",\"physics.ins-det\"]","methods":"[]","has_code":false}
