{"ID":2859293,"CreatedAt":"2026-06-01T04:54:23.091178241Z","UpdatedAt":"2026-06-01T04:54:23.091178241Z","DeletedAt":null,"paper_url":"https://arxiv.org/abs/2510.05819","arxiv_id":"2510.05819","title":"Deformable Image Registration for Self-supervised Cardiac Phase Detection in Multi-View Multi-Disease Cardiac Magnetic Resonance Images","abstract":"Cardiovascular magnetic resonance (CMR) is the gold standard for assessing cardiac function, but individual cardiac cycles complicate automatic temporal comparison or sub-phase analysis. Accurate cardiac keyframe detection can eliminate this problem. However, automatic methods solely derive end-systole (ES) and end-diastole (ED) frames from left ventricular volume curves, which do not provide a deeper insight into myocardial motion. We propose a self-supervised deep learning method detecting five keyframes in short-axis (SAX) and four-chamber long-axis (4CH) cine CMR. Initially, dense deformable registration fields are derived from the images and used to compute a 1D motion descriptor, which provides valuable insights into global cardiac contraction and relaxation patterns. From these characteristic curves, keyframes are determined using a simple set of rules. The method was independently evaluated for both views using three public, multicentre, multidisease datasets. M\u0026Ms-2 (n=360) dataset was used for training and evaluation, and M\u0026Ms (n=345) and ACDC (n=100) datasets for repeatability control. Furthermore, generalisability to patients with rare congenital heart defects was tested using the German Competence Network (GCN) dataset. Our self-supervised approach achieved improved detection accuracy by 30% - 51% for SAX and 11% - 47% for 4CH in ED and ES, as measured by cyclic frame difference (cFD), compared with the volume-based approach. We can detect ED and ES, as well as three additional keyframes throughout the cardiac cycle with a mean cFD below 1.31 frames for SAX and 1.73 for LAX. Our approach enables temporally aligned inter- and intra-patient analysis of cardiac dynamics, irrespective of cycle or phase lengths. GitHub repository: https://github.com/Cardio-AI/cmr-multi-view-phase-detection.git","short_abstract":"Cardiovascular magnetic resonance (CMR) is the gold standard for assessing cardiac function, but individual cardiac cycles complicate automatic temporal comparison or sub-phase analysis. Accurate cardiac keyframe detection can eliminate this problem. However, automatic methods solely derive end-systole (ES) and end-dia...","url_abs":"https://arxiv.org/abs/2510.05819","url_pdf":"https://arxiv.org/pdf/2510.05819v1","authors":"[\"Sven Koehler\",\"Sarah Kaye Mueller\",\"Jonathan Kiekenap\",\"Gerald Greil\",\"Tarique Hussain\",\"Samir Sarikouch\",\"Florian André\",\"Norbert Frey\",\"Sandy Engelhardt\"]","published":"2025-10-07T11:40:17Z","proceeding":"cs.CV","tasks":"[\"cs.CV\",\"cs.AI\"]","methods":"[]","has_code":false,"code_links":[{"ID":608625,"CreatedAt":"2026-06-01T04:54:23.091178241Z","UpdatedAt":"2026-06-01T04:54:23.091178241Z","DeletedAt":null,"paper_id":2859293,"paper_url":"https://arxiv.org/abs/2510.05819","paper_title":"Deformable Image Registration for Self-supervised Cardiac Phase Detection in Multi-View Multi-Disease Cardiac Magnetic Resonance Images","repo_url":"https://github.com/Cardio-AI/cmr-multi-view-phase-detection.git","is_official":false,"mentioned_in_paper":false,"mentioned_in_github":true,"github_stars":0}]}
