{"ID":2850312,"CreatedAt":"2026-06-01T04:54:23.091178241Z","UpdatedAt":"2026-06-01T04:54:23.091178241Z","DeletedAt":null,"paper_url":"https://arxiv.org/abs/2510.22301","arxiv_id":"2510.22301","title":"AnyECG-Lab: An Exploration Study of Fine-tuning an ECG Foundation Model to Estimate Laboratory Values from Single-Lead ECG Signals","abstract":"Timely access to laboratory values is critical for clinical decision-making, yet current approaches rely on invasive venous sampling and are intrinsically delayed. Electrocardiography (ECG), as a non-invasive and widely available signal, offers a promising modality for rapid laboratory estimation. Recent progress in deep learning has enabled the extraction of latent hematological signatures from ECGs. However, existing models are constrained by low signal-to-noise ratios, substantial inter-individual variability, limited data diversity, and suboptimal generalization, especially when adapted to low-lead wearable devices. In this work, we conduct an exploratory study leveraging transfer learning to fine-tune ECGFounder, a large-scale pre-trained ECG foundation model, on the Multimodal Clinical Monitoring in the Emergency Department (MC-MED) dataset from Stanford. We generated a corpus of more than 20 million standardized ten-second ECG segments to enhance sensitivity to subtle biochemical correlates. On internal validation, the model demonstrated strong predictive performance (area under the curve above 0.65) for thirty-three laboratory indicators, moderate performance (between 0.55 and 0.65) for fifty-nine indicators, and limited performance (below 0.55) for sixteen indicators. This study provides an efficient artificial-intelligence driven solution and establishes the feasibility scope for real-time, non-invasive estimation of laboratory values.","short_abstract":"Timely access to laboratory values is critical for clinical decision-making, yet current approaches rely on invasive venous sampling and are intrinsically delayed. Electrocardiography (ECG), as a non-invasive and widely available signal, offers a promising modality for rapid laboratory estimation. Recent progress in de...","url_abs":"https://arxiv.org/abs/2510.22301","url_pdf":"https://arxiv.org/pdf/2510.22301v1","authors":"[\"Yujie Xiao\",\"Gongzhen Tang\",\"Wenhui Liu\",\"Jun Li\",\"Guangkun Nie\",\"Zhuoran Kan\",\"Deyun Zhang\",\"Qinghao Zhao\",\"Shenda Hong\"]","published":"2025-10-25T14:04:26Z","proceeding":"cs.LG","tasks":"[\"cs.LG\",\"cs.AI\"]","methods":"[\"LoRA\"]","has_code":false}
